Compact flame detector KLC 11 EX
The UV flame detector KLC 11 EX is designed for industrial use in ATEX Zone 1 areas that do not require a continuous operation approved flame detector and whose control only requires an open collector output.
The UV flame detector KLC 11 EX is designed for industrial use in ATEX Zone 1 areas that do not require a continuous operation approved flame detector and whose control only requires an open collector output.
The KLC 11 EX is a compact flame detector specially designed for single burner firing systems that produce almost no radiation in the visible light spectrum or operate with very low flame modulation. The UV tube used ensures that background radiation, e.g. from glowing brick linings or mixing equipment parts, is not detected.
The flame signal intensity can be easily recognised via an LED as a visual indicator. The KLC 11 EX can be connected directly to the ionisation or LDR input of the automatic burner control system. It is compatible in its dimensions, connection dimensions and pin assignment with other devices from the KLC series. All accessories are therefore identical and reduce the variety of parts in production and service.
The flame detector KLC 11 EX is designed in accordance with EN298:2012-11 for automatic burner control systems which check whether a flame signal is still present after the control shutdown, although the flame amplifier is permanently energised. The flame monitor must be disconnected from the mains at least once in 24 hours and restarted.
Do you have a question about our service portfolio, need planning support for a project or are you looking for a specialist in flame monitoring? Then please contact us.
Do you have a question about our service portfolio, need planning support for a project or are you looking for a specialist in flame monitoring? Then please contact us.
Dear Ladies and Gentlemen,
Already in July 2021 BFI Automation Mindermann GmbH and BST Solutions GmbH have jointly created the brand name FLAMONITEC® in order to increase awareness especially outside Europe.
Hereby, we want to express our core competence in short form: Flame Monitoring Technology. And this in the entire bandwidth.
Since 2004, BST Solutions GmbH has been active in the field of flame monitoring for original equipment manufacturers of heating technology and industrial firing equipment. For this BST Solutions GmbH uses the experience and patents of BFI Automation Mindermann GmbH, which has been active in the field of flame monitoring for power plants, petrochemical plants and gas turbines since 1973.
These experiences have encouraged us to cooperate more closely also economically. On 31.05.2023 BFI Automation Mindermann GmbH has taken over all shares of BST Solutions GmbH retroactively to 01.01.2023.
Both companies merge to form BFI Automation Mindermann GmbH.
Through this merger, all business activities will be transferred to BFI Automation Mindermann GmbH with immediate effect. As part of this change, you can expect a seamless transition in our day-to-day business. Our dedicated team members will continue to serve you with the same level of professionalism, efficiency and attention to detail.
We are confident that this change will help us serve you even better and provide you with even greater value in the flame monitoring field.
Please do not hesitate to contact us personally for further information.